United Arab Emirates – 2009

Specifications:

Heater

Components:
  • Design of Heater (20 x 13 m, height 52 m)
  • Tonnage of Steel 590 tons
Special Challenges:
  • link at height 23 meters to the nearby steel casing of “reactor” with coexisting restriction of deflections H / 300
Regulations:
  • UBC 1997 for loads out of Wind
  • UBC 1997 for loads out of earthquake
  • AISC for design of steel structure