Germany – 2017
Specifications:
Steel casing for vertical cryogenic storage tanks
Components:
- Steel casing for increased mounting height (h = 2,50m) of vertical storage
- tanks up to capacities of 49.000 Liters
Special Challenges:
- Evaluation of higher stresses to the structure of the storage tank
- Design of steel casing to a minimum of deflections
- Proof of existing foundation for new loads
- Subsequent anchoring on existing foundation
Normen:
- DIN EN 1991 for loads out of Wind, Snow and live loads
- EN 1992 /1993 / 1995 / 1997 design of concrete / steel structure / soil mechanics